Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model

13Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background and aim Local hemodynamic changes are one of the main factors that determine the vessel wall biological response after stent/scaffold implantation. Computational fluid dynamic studies provide an opportunity to investigate the rheological effects of implanted stent/scaffold. The aim of this study was to assess the local hemodynamic microenvironment in scaffolded segments in porcine coronary models. Methods In six epicardial coronary arteries of healthy mini-pigs, six Absorb bioresorbable vascular scaffolds (Absorb BVS) were implanted. Optical coherence tomography(OCT) was performed after scaffold implantation and the images were fused with the angiographic data to reconstruct the three-dimensional coronary artery anatomy. Blood flow simulations were performed, and endothelial shear stress(ESS) distribution was estimated for each scaffolded segment. In a linear mixed-effect model, the contributing factors for low (< 1.0 Pa) ESS levels were assessed. At 30-day post-implantation, histopathological assessment was performed at 2 scaffolds. Results In scaffolded segments, the median ESS was 0.57 (IQR: 0.29–0.99) Pa. In linear mixed-effect analysis, cross-section area was associated with low shear stress levels. In scaffolded segments, the percentage of the recirculation zone per scaffolded luminal surface was 3.26 ± 2.07%. At 30-day histopathological assessment of implanted vessel segments revealed minimal injury score, minimal neointimal inflammation and minimal adventitial inflammation scores with moderate endothelial coverage. Fibrin accumulation was seen at 95.69 ± 2.47% of the struts. Conclusion The thick rectangular strut design of the Absorb BVS incited flow disruptions with low shear stress inducing fibrin accumulation. CFD assessment can be used to guide improvements in the scaffold design for a more “hemo-compatible” geometry.

Cite

CITATION STYLE

APA

Tenekecioglu, E., Torii, R., Bourantas, C., Abdelghani, M., Cavalcante, R., Sotomi, Y., … Serruys, P. W. (2017). Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model. International Journal of Cardiology, 227, 467–473. https://doi.org/10.1016/j.ijcard.2016.11.005

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free