Abstract
Headed studs are nowadays the standard steel-concrete connectors because of their competitive advantages. Firstly, they provide a high degree of safety thanks to semiautomatic electric arc welding. These welds are not suitable for typical non-destructive tests. The analytical study comprises several models. The first vibration modes have been obtained. The experimental research has developed first the measurement of the natural frequencies of 28 headed-studs in the sonic range. Then they have been tested by non-destructive and destructive tests. Finally theirs tests have been compared with their respective frequency measurements. A clear relationship between the measured frequencies and the lack of penetration of the welds has been established, that confirms the analytical prediction of this effect of the internal weld imperfections. Therefore, the feasibility of simple and absolutely non-destructive tests of welded studs by in site measurement of natural frequencies in the sonic range has been clearly established in this work.
Author supplied keywords
Cite
CITATION STYLE
Aznar, A., Cervera, J., Ortiz, J., & Hernando, J. I. (2012). Ensayo no destructivo de soldaduras en pernos conectores mediante inspección acústica. Informes de La Construccion, 64(527), 371–380. https://doi.org/10.3989/ic.11.017
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.