Transvenous cryo-ablation of the slow pathway for the treatment of atrioventricular nodal re-entrant tachycardia: A single-centre initial experience study

36Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims: Within the last several years, transvenous cryo-ablation has become an alternative method to perform ablation of the slow-pathway. This study evaluated the acute and long-term safety and effectiveness of atrio-ventricular nodal re-entrant tachycardia (AVNRT) cryo-ablation. Methods and results: The first 69 consecutive patients with AVNRT (60 slow-fast, 4 fast-slow, and 5 slow-slow) who underwent slow-pathway cryo-ablation were included. Mean age was 37 ± 15, body weight 68 ± 14 kg, symptom duration 125 ± 104 months, and number of ineffective antiarrhythmic (AA) drugs 1.8 ± 1.4. A 7 Fr cryo-catheter (Cryocath®) was used, with initially 4-mm-tip and later with 6-mm-tip electrode. Cryo-mapping (n = 7.9 ± 8.4 per pt) was performed at the temperature of -30°C to test the effect on the target ablation site. Successful cryo-mapping was defined as abolition of nodal conduction jump or AV nodal refractory period prolongation. Cryo-ablation (n = 5.1 ± 4.9 per pt) was then applied by freezing to -75°C for 4 min in duration if no AV-block occurred. Acute procedural success (defined as AVNRT non-inducibility) after the first cryo-ablation attempt was achieved in 60/69 patients (87%). During cryo-ablation, inadvertent transient AV-block was encountered in 14 patients (five I AV-block and nine II-III AV-block). A mid-septal target site was the only variable correlated with inadvertent AV-block occurrence during cryo-ablation (P < 0.02). Long-term clinical success after cryo-ablation was globally achieved in 56/66 (85%) with a mean follow-up of 18 ± 9 months (3 pts dropped-out). After the first procedure, 41/66 (62%) had no relapse, eight had a dramatic reduction in AVNRT duration-frequency and considered themselves cured, and five needed previously ineffective AA (with no relapse in three, drastic reduction in AVNRT duration-frequency in two). The five last patients needed one or more procedures, after which one had no recurrence and one had reduction in duration-frequency. Absence of recurrence after the first procedure was positively correlated with 6-mm-tip cryo-catheter use (<0.001) and negatively with acute procedural success (<0.001). At multivariate analysis, both were independently significant (<0.04 and <0.008, respectively). Long-term clinical success was correlated only with 6-mm-tip cryo-catheter use (<0.001). Conclusions: Slow pathway cryo-ablation is associated with an acute success but a higher recurrence rate. A 6-mm-tip cryo-catheter seems to assure during cryo-ablation a large acute and long-term success. AV-block seems non-guaranteed by a negative cryo-mapping, stressing on need of a careful surveillance. Nevertheless, the theoretical advantage of avoiding the risk of permanent AV-block when compared with radiofrequency needs larger series to be demonstrated. © The European Society of Cardiology 2007. All rights reserved.

Cite

CITATION STYLE

APA

De Sisti, A., Tonet, J., Barakett, N., Lacotte, J., Leclercq, J. F., & Frank, R. (2007). Transvenous cryo-ablation of the slow pathway for the treatment of atrioventricular nodal re-entrant tachycardia: A single-centre initial experience study. Europace, 9(6), 401–406. https://doi.org/10.1093/europace/eum031

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free