S-parameter-based defect localization for ultrasonic guidedwave SHM+

5Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

In this work, an approach for enabling miniaturized, low-voltage hardware for active structural health monitoring (SHM) based on ultrasonic guided waves is investigated. The proposed technique relies on S-parameter measurements instead of time-domain pulsing and thereby trades off longer measurement times with lower actuation voltages for improved compatibility with dense complementary metal-oxide-semiconductor (CMOS) chip integration. To demonstrate the feasibility of this method, we present results showing the successful localization of defects in aluminum and carbon-fiber-reinforced polymer (CFRP) test structures using S-parameter measurements. The S-parameter measurements were made on benchtop vector network analyzers that actuate the piezoelectric transducers at output voltage amplitudes as low as 1.264 Vpp.

Cite

CITATION STYLE

APA

Nyikayaramba, G., & Murmann, B. (2020). S-parameter-based defect localization for ultrasonic guidedwave SHM+. Aerospace, 7(3). https://doi.org/10.3390/aerospace7030033