Accuracy and dosimetric parameters comparison of 3D-printed non-coplanar template-assisted computed tomography-guided iodine-125seed ablative brachytherapy in pelvic lateral recurrence of gynecological carcinomas

15Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To investigate the accuracy of needle distribution and dosimetric parameter differences of 3D-printing non-coplanar template (3D-PNCT)-assisted computed tomography (CT)-guided iodine-125seed ablative brachytherapy (125I-SAB) in gynecological cancer patients with non-central pelvic recurrence between pre-operative plan and post-operative plan. Material and methods: Thirty-eight patients with forty-one non-central pelvic recurrent gynecological carcinomas after radiotherapy were enrolled in this study. All patients received 3D-PNCT-assisted CT-guided 125I-SAB from January 2016 to January 2019. The position, angle, and depth of seed needles were measured in both pre-operative plan and intra-operative real-time plan in brachytherapy treatment planning system (B-TPS). Dosimetric parameters of D90, D100, V100, V150, and V200as well as quality parameters of conformal index (CI), external index (EI), and homogeneity index (HI) were compared between pre-operative plan and post-operative plan. Peri-operation complications and radiation-related toxicity were assessed. Results: Median follow-up time was 12 months (range, 5-34 months). Prescribed dose was 100-170 Gy (median, 120 Gy). Radioactivity of 125I seed was 0.4-0.7 mCi (median, 0.55 mCi). Mean depth deviation for 499 needles was 0.8 ±1.0 cm. Mean angular deviation was 2.2 ±2.1 degrees. Mean tip distance deviation of needles was 0.4 ±0.3 cm. There were significant differences between pre-operative and post-operative plans in CI (p = 0.001) and EI (p = 0.005). No significant differences were shown in D90, D100, V100, V150, V200, and HI between pre-operative and post-operative plans. Only few patients suffered from = grade 2 toxicities. Conclusions: 3D-PNCT-assisted CT-guided 125I-SAB is safe and feasible for non-central pelvic recurrence of gynecological cancer. All complications are tolerable and mild.

Cite

CITATION STYLE

APA

Qu, A., Jiang, P., Wei, S., Jiang, Y., Ji, Z., Sun, H., … Wang, J. (2021). Accuracy and dosimetric parameters comparison of 3D-printed non-coplanar template-assisted computed tomography-guided iodine-125seed ablative brachytherapy in pelvic lateral recurrence of gynecological carcinomas. Journal of Contemporary Brachytherapy, 13(1), 39–45. https://doi.org/10.5114/JCB.2021.103585

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free