Abstract
Relative timing jitter between synchronized Q-switched lasers, or lack thereof, is important for stable sum-frequency generation. Experimental investigation of two passively synchronized lasers shows that the jitter is minimized when the free-running repetition rates of the two lasers are close to, but not exactly, matching. When the free-running repetition rates are matched, the jitter is significantly large. At the best operating point, the pulse-to-pulse period was 200 μs, while the relative jitter between the two lasers was 9 ns. If the effect of the master laser's pulse-to-pulse jitter is removed, the residual timing jitter between the two lasers was 6 ns, which corresponds to the lower limit set by pump power fluctuations and noise from spontaneous emission.
Cite
CITATION STYLE
Cheng, H. P. H., Tidemand-Lichtenberg, P., Jensen, O. B., Andersen, P. E., Petersen, P. M., & Pedersen, C. (2011). Experimental investigation of relative timing jitter in passively synchronized Q-switched lasers. Optics Letters, 36(3), 415. https://doi.org/10.1364/ol.36.000415