Micro-Raman study of stress distribution in local isolation structures and correlation with transmission electron microscopy

138Citations
Citations of this article
48Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Stress in local isolation structures is studied by micro-Raman spectroscopy. The results are correlated with predictions of an analytical model for the stress distribution and with cross-sectional transmission electron microscopy observations. The measurements are performed on structures on which the Si3N4 oxidation mask is still present. The influence of the pitch of the periodic local isolation pattern, consisting of parallel lines, the thickness of the mask, and the length of the bird's beak on the stress distribution are studied. It is found that compressive stress is present in the Si substrate under the center of the oxidation mask lines, with a magnitude dependent on the width of the lines. Large tensile stress is concentrated under the bird's beak and is found to increase with decreasing length of the bird's beak and with increasing thickness of the Si 3N4 film.

Cite

CITATION STYLE

APA

De Wolf, I., Vanhellemont, J., Romano-Rodríguez, A., Norström, H., & Maes, H. E. (1992). Micro-Raman study of stress distribution in local isolation structures and correlation with transmission electron microscopy. Journal of Applied Physics, 71(2), 898–906. https://doi.org/10.1063/1.351311