Intercomparison of atmospheric water vapor soundings from the differential absorption lidar (DIAL) and the solar FTIR system on Mt. Zugspitze

37Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

We present an intercomparison of three years of measurements of integrated water vapor (IWV) performed by the mid-infrared solar FTIR (Fourier Transform Infra-Red) instrument on the summit of Mt. Zugspitze (2964 m a.s.l.) and by the nearby near-infrared differential absorption lidar (DIAL) at the Schneefernerhaus research station (2675 m a.s.l.). The solar FTIR was shown to be one of the most accurate and precise IWV sounders in recent work (Sussmann et al., 2009) and is taken as the reference here. By calculating the FTIR-DIAL correlation (22 min coincidence interval, 15 min integration time) we derive an almost ideal slope of 0.996 (10), a correlation coefficient of R = 0.99, an IWV intercept of -0.039 (42) mm (-1.2 % of the mean), and a bias of -0.052 (26) mm (-1.6 % of the mean) from the scatter plot. By selecting a subset of coincidences with an optimum temporal and spatial matching between DIAL and FTIR, we obtain a conservative estimate of the precision of the DIAL in measuring IWV which is better than 0.1 mm (3.2 % of the mean). We found that for a temporal coincidence interval of 22 min the difference in IWV measured by these two systems is dominated by the volume mismatch (horizontal distance: 680 m). The outcome from this paper is twofold: (1) the IWV soundings by FTIR and DIAL agree very well in spite of the differing wavelength regions with different spectroscopic line parameters and retrieval algorithms used. (2) In order to derive an estimate of the precision of state-of-the-art IWV sounders from intercomparison experiments, it is necessary to use a temporal matching on time scales shorter than 10 min and a spatial matching on the 100-m scale. © Author(s) 2011.

References Powered by Scopus

The HITRAN 2008 molecular spectroscopic database

3243Citations
N/AReaders
Get full text

The HITRAN molecular spectroscopic database: Edition of 2000 including updates through 2001

1089Citations
N/AReaders
Get full text

Earth's Annual Global Mean Energy Budget

1082Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Field-deployable diode-laser-based differential absorption lidar (DIAL) for profiling water vapor

95Citations
N/AReaders
Get full text

35 Yr of stratospheric aerosol measurements at Garmisch-Partenkirchen: From Fuego to Eyjafjallajökull, and beyond

58Citations
N/AReaders
Get full text

Assessment of small-scale integrated water vapour variability during HOPE

55Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Vogelmann, H., Sussmann, R., Trickl, T., & Borsdorff, T. (2011). Intercomparison of atmospheric water vapor soundings from the differential absorption lidar (DIAL) and the solar FTIR system on Mt. Zugspitze. Atmospheric Measurement Techniques, 4(5), 835–841. https://doi.org/10.5194/amt-4-835-2011

Readers' Seniority

Tooltip

Researcher 7

70%

PhD / Post grad / Masters / Doc 2

20%

Professor / Associate Prof. 1

10%

Readers' Discipline

Tooltip

Earth and Planetary Sciences 9

75%

Physics and Astronomy 2

17%

Environmental Science 1

8%

Save time finding and organizing research with Mendeley

Sign up for free