Small-Perturbation Electrochemical Impedance Spectroscopy System With High Accuracy for High-Capacity Batteries in Electric Vehicles

9Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.
Get full text

Abstract

—This article presents an electrochemical impedance spectroscopy (EIS) system optimized for high-capacity electric vehicle (EV) batteries, prioritizing high measurement accuracy with minimal current perturbation while reducing measurement time. The system incorporates a switched-resistor high-pass filter for accurate ac voltage measurement and a low-noise amplifier for signal amplification. It also features two parallel low-pass filters with tailored bandwidths (0.2 Hz for 1–9 Hz and 1 Hz for 10–1 k Hz), significantly enhancing accuracy and reducing settling time. In addition, the small current perturbation approach improves safety and simplifies the analysis process. Our prototype achieves precise impedance measurement with a standard deviation of less than 10.4 μΩ for high-precision resistors and less than 14 μΩ root-mean-square error in magnitude for a 70 Ah battery across 1–1 k Hz frequency range and 20–80% state-of-charge range at 25◦C temperature. These findings demonstrate the proposed EIS system’s effectiveness in the accurate assessment and health monitoring of large EV batteries.

Cite

CITATION STYLE

APA

Lee, Y. N., Jo, S. W., Rahim, G., Lee, S. G., & Kwon, K. (2025). Small-Perturbation Electrochemical Impedance Spectroscopy System With High Accuracy for High-Capacity Batteries in Electric Vehicles. IEEE Transactions on Industrial Electronics, 72(3), 3202–3212. https://doi.org/10.1109/TIE.2024.3436676

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free