Abstract
Purpose: The Controlled Attenuation Parameter (CAP score) is based on ultrasonic properties of retropropagated radiofrequency signals acquired by FibroscanTM (Echosens, Paris, France). Since ultrasound propagation is influenced by the presence of fat, CAP score was developed to quantify steatosis. The aim of this study was to delineate the accuracy of CAP in diagnosing hepatic steatosis, compared to the gold standard of liver biopsy. Patients and Methods: A total of 150 patients underwent same-day liver biopsy and measurement of hepatic steatosis with Fibroscan. Only examinations with 10 satisfactory measurements, and an inter-quartile range of less than 30% of the median liver stiffness values were included for data analysis. Histological staging was then correlated with median values and Spearman correlation calculated. P values of < 0.05 were considered statistically significant. Results: For diagnosis of hepatic steatosis (HS), CAP could predict the steatosis S2 with AUROC 0.815 (95% CI 0.741– 0.889), sensitivity (0.81) and specificity (0.73) when the optimal cut-off value was set at 288 dB/m. CAP detected histological grade S3 with AUROC 0.735 (95% CI 0.618– 0.851), sensitivity (0.71) and specificity (0.74), with a cut-off value of 330 dB/m. The AUROC for steatosis grade S1 was 0.741 (95% CI 0.650– 0.824), with a cut-off value of 263 dB/m with sensitivity 0.75 and specificity 0.70. Univariate analysis showed a correlation between CAP and diabetes (p 0.048). Conclusion: The performance of CAP to diagnose steatosis severity decreases as steatosis progresses. CAP is associated with diabetes but not other clinical factors and parameters of the metabolic syndrome. [ABSTRACT FROM AUTHOR] Copyright of Hepatic Medicine: Evidence & Research is the property of Dove Medical Press Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Cite
CITATION STYLE
Atzori, S., Pasha, Y., Maurice, J. B., Taylor-Robinson, S. D., Campbell, L., & Lim, A. K. (2023). The Accuracy of Ultrasound Controlled Attenuation Parameter in Diagnosing Hepatic Fat Content. Hepatic Medicine: Evidence and Research, Volume 15, 51–61. https://doi.org/10.2147/hmer.s411619
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.