Effects of different extraction protocols on endotoxin analyses of airborne grain dusts

34Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

The detection of gram-negative bacterial endotoxins in occupational dusts, specifically those from agricultural environments, is of increasing importance in research on occupational lung disease. In this study, the quantitative chromogenic Limulus amebocyte lysate test for the detection of endotoxins in airborne dusts from spring wheat and oats was examined. Different extraction fluids were tested, as were the effects of time on extraction and of repeated freeze-thaw cycles on the extracts. The data suggest that the chromogenic method can be used effectively in the analysis of environmental dusts or their frozen extracts for endotoxin quantitation. Water appears to be the preferable extraction medium, and the length of extraction time may affect the results.

Cite

CITATION STYLE

APA

Olenchock, S. A., Lewis, D. M., & Mull, J. C. (1989). Effects of different extraction protocols on endotoxin analyses of airborne grain dusts. Scandinavian Journal of Work, Environment and Health, 15(6), 430–435. https://doi.org/10.5271/sjweh.1830

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free