Worst-case IR-drop monitoring with 1GHz sampling rate

11Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

IR-drop monitoring has been an effective means to assess the power integrity in real silicon. Existing methods, however, fail to achieve a high accuracy and a high sampling rate simultaneously. In this paper, we present a novel method to resolve this dilemma. First of all, we focus on the measurement of the worst-case IR-drop, instead of the entire sampled VDD waveform. This strategy can make a high sampling rate easily viable. Secondly, we perform periodic calibration to account for not only the process variation but also the temperature change. Post-layout simulation indicates that this method can support 1 GHz sample rate while keeping the measurement error less than 4.81 mV at the same time. © 2013 IEEE.

Cite

CITATION STYLE

APA

Hsu, C. H., Huang, S. Y., Kwai, D. M., & Chou, Y. F. (2013). Worst-case IR-drop monitoring with 1GHz sampling rate. In 2013 International Symposium on VLSI Design, Automation, and Test, VLSI-DAT 2013. https://doi.org/10.1109/VLDI-DAT.2013.6533865