Abstract
Due to the paucity of studies regarding the seismic assessment of buildings in Brazil, this study aims to present and discuss a seismic reliability assessment of a reinforced concrete framed structure designed according to the Brazilian standard ABNT NBR 6118:2014 without the consideration of the seismic design requirements of ABNT NBR 15421:2006. Herein, fragility functions are generated through probabilistic seismic demand analysis, and integrated with hazard curves for Northeastern Brazil to generate regional failure probability maps for three limit-states: Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). The results indicated that the building performance is adequate for IO; however, for LS and CP, an unacceptable performance is observed.
Author supplied keywords
Cite
CITATION STYLE
Pereira, E. M. V., Cavalcante, G. H. F., Rodrigues, I. D., Vieira Júnior, L. C. M., & Siqueira, G. H. (2022). Seismic reliability assessment of a non-seismic reinforced concrete framed structure designed according to ABNT NBR 6118:2014. Revista IBRACON de Estruturas e Materiais, 15(1). https://doi.org/10.1590/S1983-41952022000100010