Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing

56Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims The accuracy of transcatheter aortic valve replacement (TAVR) sizing using three-dimensional transoesophageal echocardiography (3D-TEE) compared with the gold-standard multi-slice computed tomography (MSCT) remains unclear. We compare aortic annulus measurements assessed using these two imaging modalities. Methods and results We performed a single-centre prospective cohort study, including 53 consecutive patients undergoing TAVR, who had both MSCT and 3D-TEE for aortic annulus sizing. Aortic annular dimensions, expected transcatheter heart valve (THV) oversizing, and hypothetical valve size selection based on CT and TEE were compared. 3D-TEE and CT cross-sectional mean diameter (r= 0.69), perimeter (r = 0.70), and area (r = 0.67) were moderately to highly correlated (all P-values,0.0001). 3D-TEE-derived measurements were significantly smaller compared with MSCT: perimeter (68.6±5.9 vs. 75.1±5.7 mm, respectively; P < 0.0001); area (345.6±64.5 vs. 426.9±68.9 mm2, respectively; P < 0.0001). The percentage difference between 3D-TEE and MSCT measurements was around 9%. Agreement between MSCT-and 3D-TEE-based THV sizing (perimeter) occurred in 44% of patients. Using the 3D-TEE perimeter annular measurements, up to 50% of patients would have received an inappropriate valve size according to manufacturerrecommended, area-derived sizing algorithms. Conclusion Aortic annulus measurements for pre-procedural TAVR assessment by 3D-TEE are significantly smaller than MSCT. In this study, such discrepancy would have resulted in up to 50% of all patients receiving the wrong THV size. 3D-TEE should be used for TAVR sizing, only when MSCT is not available or contraindicated. The clinical impact of this information requires further study.

Cite

CITATION STYLE

APA

Vaquerizo, B., Spaziano, M., Alali, J., Mylote, D., Theriault-Lauzier, P., Alfagih, R., … Piazza, N. (2016). Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing. European Heart Journal Cardiovascular Imaging, 17(1), 15–23. https://doi.org/10.1093/ehjci/jev238

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free