Comparison between Amplatzer and Watchman Left Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation: A Systematic Review and Meta-Analysis

8Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction: The Amplatzer and Watchman left atrial appendage closure (LAAC) devices are the two most frequently used devices for LAAC devices worldwide. This meta-analysis aimed to compare the safety and efficacy of the two devices. Methods: We searched the PubMed, EMBASE, and the Cochrane Library for studies up to February 6, 2022 that compared the safety and efficacy of the Amplatzer and Watchman devices. Results: Fifteen studies including 2,150 patients in randomized controlled trials and 2,526 patients in observational studies were included in the meta-analysis. Amplatzer device was associated with higher rates of major procedure-related complications (odds ratio [OR]: 1.99, 95% confidence interval [CI]: 1.45-2.74, p < 0.0001) and device embolization (OR: 1.99, 95% CI: 1.09-3.64, p = 0.03). However, Amplatzer device had lower rates of total peridevice leak (PDL) (OR: 0.48, 95% CI: 0.27-0.83, p = 0.009), significant PDL (OR: 0.27, 95% CI: 0.12-0.57, p = 0.0007) and device-related thrombus (DRT) (OR: 0.67, 95% CI: 0.48-0.95, p = 0.02). No statistical differences were observed between the two devices in other safety and efficacy endpoints, such as pericardial effusion, cardiac tamponade, air embolism, vascular complications, ischemic stroke/transient ischemic attack (TIA), hemorrhagic stroke, all-cause death, cardiovascular death, and bleeding. Conclusions: Amplatzer LAAC device was associated with higher rates of major procedure-related complications, especially in device embolization. Watchman LAAC device was associated with higher rates of PDL and DRT. There were no significant differences between two devices in ischemic stroke/TIA, hemorrhagic stroke, all-cause death, cardiovascular death, and bleeding.

Cite

CITATION STYLE

APA

Qiao, J., Zhang, B., Wang, J., Pan, L., Cheng, T., Wang, Y., & Xiong, E. (2022, July 1). Comparison between Amplatzer and Watchman Left Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation: A Systematic Review and Meta-Analysis. Cardiology (Switzerland). S. Karger AG. https://doi.org/10.1159/000524626

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free