Abstract
Energy transfer processes from ELM-like pulsed helium (He) plasmas with a pulse duration of ∼0.1 ms to aluminum (Al) and tungsten (W) surfaces were experimentally investigated by the use of a magnetized coaxial plasma gun device. The surface absorbed energy density of the He pulsed plasma on the W surface measured with a calorimeter was ∼0.44 MJ m-2, whereas it was ∼0.15 MJ m-2 on the Al surface. A vapor layer in front of the Al surface exposed to the He pulsed plasma was clearly identified by Al neutral emission line (Al i) measured with a high time resolution spectrometer, and fast imaging with a high-speed visible camera filtered around the Al i emission line. On the other hand, no clear evaporation in front of the W surface exposed to the He pulsed plasma was observed in the present condition. Discussions on the reduction in the surface absorbed energy density on the Al surface are provided by considering the latent heat of vaporization and radiation cooling due to the Al vapor cloud.
Author supplied keywords
Cite
CITATION STYLE
Kikuchi, Y., Sakuma, I., Asai, Y., Onishi, K., Isono, W., Nakazono, T., … Nagata, M. (2016). Vapor shielding effects on energy transfer from plasma-gun generated ELM-like transient loads to material surfaces. In Physica Scripta (Vol. 2016). Institute of Physics Publishing. https://doi.org/10.1088/0031-8949/T167/1/014065