The influence of a column shape cross-section on the punching capacity

3Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

The article deals with non-linear modeling of slab-column connection which represents a fragment of flat slab supported by a column and loaded up to the punching shear failure. The aim of this parametrical study is the analysis of the length of reduced control perimeters in the case of columns with significantly elongated rectangular cross-section. The non-linear analysis was performed in program Atena and calibrated by test results obtained from the laboratory experiments carried out at Slovak University of Technology in Bratislava. The results of non-linear analysis are compared with the values of shear resistance calculated according to the current Eurocode 2 model; fib Model Code 2010 and model proposed for the second generation of Eurocode 2 based on the Critical shear crack theory. The reliability of the models is evaluated by comparison of the results of numerical analyses and previously mentioned design models.

Cite

CITATION STYLE

APA

Sarvaicova, S., Borzovic, V., & Augustin, T. (2019). The influence of a column shape cross-section on the punching capacity. In Selected Papers of the 13th International Conference “Modern Building Materials, Structures and Techniques”, MBMST 2019 (pp. 455–462). Vilnius Gediminas Technical University Publishing House “Technika.” https://doi.org/10.3846/mbmst.2019.094

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free