Firesorb bioresorbable scaffold for de novo coronary artery disease: 1-year clinical outcomes

4Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The first-generation bioresorbable scaffolds (BRS) have been associated with higher rates of device-related adverse outcomes in comparison to everolimus-eluting stents. We aimed to evaluate the efficacy and safety of the thinner-strut (100/125 μm) poly-L-lactic acid-based sirolimus-eluting Firesorb BRS in patients with de novo coronary lesions. Methods: Patient-level data derived from 1205 patients in the FUTURE-II RCT (n = 215) and FUTURE-III registry (n = 990) were prospectively collected, pooled, and analyzed. The primary endpoint of 1-year target lesion failure (TLF) was defined as a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. The patient-oriented composite endpoint (POCE) of all-cause death, any myocardial infarction, or any revascularization was also analyzed. Results: At 1-year follow-up, the cumulative rate of TLF was 1.67%, with an upper 95% confidence interval of 2.57%, significantly lower than the objective performance criterion goal of 6.6% (P < 0.001). The rate of single TLF components was 0.42% for cardiac death, 0.92% for target vessel myocardial infarction, and 0.42% for ischemia-driven target lesion revascularization. The cumulative rate of POCE at 1 year was 3.34%. No patient experienced definite or probable device thrombosis during 1-year follow-up. Conclusions: This pooled, patient-level analysis indicates that the thinner strut Firesorb BRS exhibits promising 1-year efficacy and safety profiles with regard to TLF. However, our findings are only applicable to non-complex lesions; large-scale randomized clinical trials powered to assess clinical endpoints are necessary to evaluate the strategy of Firesorb BRS compared to drug-eluting stents. Trial registration: ClinicalTrials.gov Identifier: NCT02890160 and NCT03660202.

Cite

CITATION STYLE

APA

Jiang, J., Li, C., Chen, D., Song, L., Cui, Z., Li, P., … Wang, J. (2025). Firesorb bioresorbable scaffold for de novo coronary artery disease: 1-year clinical outcomes. BMC Medicine, 23(1). https://doi.org/10.1186/s12916-025-04254-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free