Abstract
Background: Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment. Methods and Results: Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm3) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; P<0.0001) and had good agreement on LV functional assessment. LV mass, however, was slightly underestimated on FB CS cine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (P<0.0001). Conclusions: Despite underestimation of LV mass, FB CS cine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.
Author supplied keywords
Cite
CITATION STYLE
Kido, T., Kido, T., Nakamura, M., Watanabe, K., Schmidt, M., Forman, C., & Mochizuki, T. (2017). Assessment of left ventricular function and mass on free-breathing compressed sensing real-time cine imaging. Circulation Journal, 81(10), 1463–1468. https://doi.org/10.1253/circj.CJ-17-0123