AR-CPR 2.0: Validation of the Accuracy and Precision of a Wearable Coaching System for Improving Chest Compression Performance

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Pediatric cardiopulmonary resuscitation (CPR) quality remains inconsistent, with low adherence to guideline-recommended compression rate and depth. Augmented reality cardiopulmonary resuscitation (AR-CPR) is an augmented reality feedback system designed to improve CPR performance using real-time, in-view coaching via smart glasses. To validate the accuracy and precision of the AR-CPR system in measuring chest compression rate and depth across clinically relevant ranges, we tested AR-CPR using a programable oscillation platform at five rates (100–140 compressions per minute (CPM)) and four depths (4.0–5.5cm), and with the Stryker LUCAS3 device at 102 CPM and 5.3cm. A total of 473 compressions (slide test) and 559 compressions (LUCAS3 test) were analyzed. Statistical methods included intraclass correlation coefficients (ICC[2,1]), paired t-tests, Bland–Altman analysis, root-mean-square error (RMSE), kernel density estimation for error distribution, and group error modeling to estimate clinical thresholds (±2.5 CPM, ±0.5cm). Linearity was assessed via linear regression. The AR-CPR system demonstrated high accuracy and reliability in 473 simulated and 559 mechanical compressions. Mean biases were minimal for rate (−0.48, −0.44 CPM) and depth (+0.39, +0.59cm), with excellent ICCs (0.997 rate, 0.944 depth). Errors were normally distributed, with <7% exceeding clinically relevant thresholds. R2 values (0.994 rate, 0.903 depth) confirmed strong linear agreement with reference values. AR-CPR reliably measured compression rate and depth with high accuracy and precision across variable and fixed testing conditions. Its portability, real-time feedback, and robust signal processing support its potential for improving pediatric resuscitation training and clinical performance.

Cite

CITATION STYLE

APA

Kleinman, K., Dean, J. L., Yu, E., Schreurs, B. A., & Jeffers, J. M. (2025). AR-CPR 2.0: Validation of the Accuracy and Precision of a Wearable Coaching System for Improving Chest Compression Performance. Journal of Medical Devices , 20(1). https://doi.org/10.1115/1.4070016

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free