Quantification of regional myocardial perfusion with generator-produced 62Cu-PTSM and positron emission tomography

58Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Background. Noninvasive assessment of regional myocardial perfusion at rest and after stress is important for the objective evaluation of the effects of coronary artery disease and its response to therapy. Centers that do not have cyclotrons rely on generator-produced radioisotopes for assessment of regional myocardial perfusion with positron emission tomography (PET). The aim of the present study was to develop and implement an approach to quantify regional myocardial perfusion using copper(II) pyruvaldehyde bis-(N4-thiosemicarbazone) (PTSM) labeled with the generator-produced, positron-emitting radionuclide 62Cu (t1/2=9.7 minutes). Methods and Results. Regional perfusion was estimated from dynamic PET scans after intravenous administration of 62Cu-PTSM in 21 studies in 13 intact dogs evaluated over a wide range of myocardial flow values. In 15 interventions in nine dogs, regional perfusion was also estimated with H215O. Regional perfusion with 62Cu-PTSM was estimated from dynamic blood and tissue time-activity curves, along with the model parameter k1 (forward rate of transport) and the PET parameter FBM (fraction of blood pool activity observed in tissue), using a two-compartment kinetic model. Arterial blood activity was corrected for red blood cell-associated 62Cu. In 44 comparisons, estimates of regional perfusion with 62Cu-PTSM correlated well with estimates obtained with concomitantly administered radiolabeled microspheres (y=0.90x±0.15, r=0.95, p<0.05) over a flow range from 0.23 to 6.14 ml/g per minute. In five healthy human volunteers evaluated at rest with H215O and 62Cu-PTSM, regional perfusion estimated with 62Cu-PTSM was not significantly different from that obtained with H215O (1.05±0.36 versus 0.96±0.28 ml/g per minute). 62Cu-PTSM provided high-quality images of the heart. Conclusions. The results of this study demonstrate that quantification of regional myocardial perfusion is feasible using generator-produced 62Cu-PTSM. Since 62Cu-PTSM can be used to estimate perfusion in the brain, kidney, and tumors as well as in the heart, it is an attractive tracer for centers that rely on generator-produced tracers for the evaluation of perfusion with PET.

Cite

CITATION STYLE

APA

Herrero, P., Markham, J., Weinheimer, C. J., Anderson, C. J., Welch, M. J., Green, M. A., & Bergmann, S. R. (1993). Quantification of regional myocardial perfusion with generator-produced 62Cu-PTSM and positron emission tomography. Circulation, 87(1), 173–183. https://doi.org/10.1161/01.CIR.87.1.173

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free