Lung-Protective Ventilation over 6 Years at a Large Academic Medical Center: An Evaluation of Trends, Adherence, and Perceptions of Benefit

5Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objectives: The main objective of this study was to evaluate trends in set tidal volumes across all adult ICUs at a large academic medical center over 6 years, with a focus on adherence to lung-protective ventilation (≤ 8-cc/kg ideal body weight). A secondary objective was to survey providers on their perceptions of lung-protective ventilation and barriers to its implementation. Design: Retrospective observational analysis (primary objective) and cross-sectional survey study (secondary objective), both at a single center. Participants: Mechanically ventilated adult patients with a set tidal volume (primary objective) and providers rotating through the Medical and Neurosciences ICUs (secondary objective). Interventions: None. Measurements and Main results: From 2013 to 2018, the average initial set tidal volume (cc/kg ideal body weight) decreased from 8.99 ± 2.19 to 7.45±1.34 (p < 0.001). The cardiothoracic ICU had the largest change in tidal volume from 11.09 ± 1.96 in 2013 to 7.97 ± 1.03 in 2018 (p < 0.001). Although the majority of tidal volumes across all ICUs were between 6.58 and 8.01 (interquartile range) in 2018, 27% of patients were still being ventilated at volumes greater than 8-cc/kg ideal body weight. Most surveyed respondents felt there was benefit to lung-protective ventilation, though many did not routinely calculate the set tidal volume in cc/kg ideal body weight, and most did not feel it was easily calculable with the current electronic medical record system. Conclusions: Despite a trend toward lower tidal volumes over the years, in 2018, over a quarter of mechanically ventilated adult patients were being ventilated with tidal volumes greater than 8 cc/kg. Survey data indicate that despite respondents acknowledging the benefits of lung-protective ventilation, there are barriers to its optimal implementation. Future modifications of the electronic medical record, including a calculator to set tidal volume in cc/kg and the use of default set tidal volumes, may help facilitate the delivery of and adherence to lung-protective ventilation.

Cite

CITATION STYLE

APA

Gao, C. A., Howard, F. M., Siner, J. M., Candido, T. D., & Ferrante, L. E. (2021). Lung-Protective Ventilation over 6 Years at a Large Academic Medical Center: An Evaluation of Trends, Adherence, and Perceptions of Benefit. Critical Care Explorations, 3(1), E0325. https://doi.org/10.1097/CCE.0000000000000325

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free