Age and sex corrected normal reference values of T1, T2 T2∗and ECV in healthy subjects at 3T CMR

92Citations
Citations of this article
155Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Myocardial T1, T2 and T2∗imaging techniques become increasingly used in clinical practice. While normal values for T1, T2 and T2∗times are well established for 1.5 Tesla (T) cardiovascular magnetic resonance (CMR), data for 3T remain scarce. Therefore we sought to determine normal reference values relative to gender and age and day to day reproducibility for native T1, T2, T2∗mapping and extracellular volume (ECV) at 3T in healthy subjects. Methods: After careful exclusion of cardiovascular abnormality, 75 healthy subjects aged 20 to 90 years old (mean 56 ± 19 years, 47% women) underwent left-ventricular T1 (3-(3)-3-(3)-5 MOLLI)), T2 (8 echo- spin echo-imaging) and T2∗(8 echo gradient echo imaging) mapping at 3T CMR (Philips Ingenia 3T and computation of extracellular volume after administration of 0.2 mmol/kg Gadovist). Inter- and intra-observer reproducibility was estimated by intraclass correlation coefficient (ICC). Day to day reproducibility was assessed in 10 other volunteers. Results: Mean myocardial T1 at 3T was 1122 ± 57 ms, T2 52 ± 6 ms, T2∗24 ± 5 ms and ECV 26.6 ± 3.2%. T1 (1139 ± 37 vs 1109 ± 73 ms, p < 0.05) and ECV (28 ± 3 vs 25 ± 2%, p < 0.001), but not T2 (53 ± 8 vs 51 ± 4, p = NS) were significantly greater in age matched women than in men. T1 (r = 0.40, p < 0.001) and ECV (r = 0.37, p = 0.001) increased, while T2 decreased significantly (r = -0.25, p < 0.05) with increasing age. T2∗was not influenced by either gender or age. Intra and inter-observer reproducibility was high (ICC ranging between 0.81-0.99), and day to day coefficient of variation was low (6.2% for T1, 7% for T2, 11% for T2∗and 11.5% for ECV). Conclusions: We provide normal myocardial T2, T2∗,T1 and ECV reference values for 3T CMR which are significantly different from those reported at 1.5 Tesla CMR. Myocardial T1 and ECV values are gender and age dependent. Measurement had high inter and intra-observer reproducibility and good day-to-day reproducibility.

Cite

CITATION STYLE

APA

Roy, C., Slimani, A., De Meester, C., Amzulescu, M., Pasquet, A., Vancraeynest, D., … Gerber, B. L. (2017). Age and sex corrected normal reference values of T1, T2 T2∗and ECV in healthy subjects at 3T CMR. Journal of Cardiovascular Magnetic Resonance, 19(1). https://doi.org/10.1186/s12968-017-0371-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free