Characteristics of laser stimulation by near infrared pulses of retinal and vestibular primary neurons

40Citations
Citations of this article
76Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background and Objective The optical stimulation of neurons from pulsed infrared lasers has appeared over the last years as an alternative to classical electric stimulations based on conventional electrodes. Laser stimulation could provide a better spatial selectivity allowing single-cell stimulation without prerequisite contact. In this work we present relevant physical characteristics of a non-lethal stimulation of cultured mouse vestibular and retinal ganglion neurons by single infrared laser pulses. Study Design/Materials and Methods Vestibular and retinal ganglion neurons were stimulated by a 100-400 mW pulsed laser diode beam (wavelengths at 1,470, 1,535, 1,875 nm) launched into a multimode optical fiber positioned at a few hundred micrometers away from the neurons. Ionic exchange measurements at the neuron membrane were achieved by whole-cell patch-clamp recordings. Stimulation and damage thresholds, duration and repetition rate of stimulation and temperature were investigated. Results All three lasers induced safe and reproducible action potentials (APs) on both types of neurons. The radiant exposure thresholds required to elicit APs range from 15 ± 5 to 100 ± 5 J cm-2 depending on the laser power and on the pulse duration. The damage thresholds, observed by a vital dye, were significantly greater than the stimulation thresholds. In the pulse duration range of our study (2-30 milliseconds), similar effects were observed for the three lasers. Measurements of the local temperature of the neuron area show that radiant exposures required for reliable stimulations at various pulse durations or laser powers correspond to a temperature increase from 22°C (room temperature) to 55-60°C. Stimulations by laser pulses at repetition rate of 1, 2, and 10 Hz during 10 minutes confirmed that the neurons were not damaged and were able to survive such temperatures. Conclusion These results show that infrared laser radiations provide a possible way to safely stimulate retinal and vestibular ganglion neurons. A similar temperature threshold is required to trigger neurons independently of variable energy thresholds, suggesting that an absolute temperature is required. Lasers Surg. Med. 44: 736-745, 2012. © 2012 Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Bec, J. M., Albert, E. S., Marc, I., Desmadryl, G., Travo, C., Muller, A., … Dumas, M. (2012). Characteristics of laser stimulation by near infrared pulses of retinal and vestibular primary neurons. Lasers in Surgery and Medicine, 44(9), 736–745. https://doi.org/10.1002/lsm.22078

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free