Objectives. Airway control is the most critical treatment. The most common and basic method of endotracheal intubation is orotracheal intubation. To perform accurate and rapid tracheal intubation, appropriate education and training are required. We developed the virtual simulation program utilizing the 3-dimensional display and haptic device to exercise orotracheal intubation, and the educational effect of this program was compared with that of the mannequin method. Method. The control group used airway mannequin and virtual intubation group was trained with new program. We videotaped both groups during objective structured clinical examination (OSCE) with airway mannequin. The video was reviewed and scored, and the rate of success and time were calculated. Result. The success rate was 78.6% in virtual intubation group and 93.3% in control group (P = 0.273). There was no difference in overall score of OSCE (21.14 ± 4.28 in virtual intubation group and 23.33 ± 4.45 in control group, P = 0.188), the time spent in successful intubation (P = 0.432), and the number of trials (P > 0.101). Conclusion. The virtual simulation with haptics had a similar effect compared with mannequin, but it could be more cost effective and convenient than mannequin training in time and space. © 2013 Dong Hoon Lee et al.
CITATION STYLE
Lee, D. H., Kim, J. G., Kim, C. W., Lee, C. H., & Lim, J. H. (2013). The usefulness of 3-dimensional virtual simulation using haptics in training orotracheal intubation. BioMed Research International, 2013. https://doi.org/10.1155/2013/534097