A case of a retained chest drain

5Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Retention of an intercostal drain segment is an uncommon and infrequently reported complication of underwater seal drain use.We report the case of a 66-year-old New Zealand European male who underwent bilateral lung transplantation for severe chronic obstructive pulmonary disease and bronchiectasis. The patient required a return to the operating room for exploratory surgery after an intercostal drain severed during its attempted removal and became retained within the chest cavity. A deep suture had inadvertently been passed around the chest drain intraoperatively. In the event of such a complication, prompt recognition and removal of the retained segment is required. This novel case is reported to highlight the possibility of an entrapped suture as a cause of resistance when attempting to remove an intercostal drain. Kinking on a chest X-ray may also point to this problem, and senior input should be sought early if radiographic findings are coupled with clinical difficulties.

Cite

CITATION STYLE

APA

Waqanivavalagi, S. W. F. R., & Chaudhuri, K. (2021). A case of a retained chest drain. Journal of Surgical Case Reports, 2021(3). https://doi.org/10.1093/jscr/rjab049