Influence of virtual monoenergetic reconstructions on coronary CT angiography-based fractional flow reserve with photon-counting detector CT: intra-individual comparison with energy-integrating detector CT

5Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: This study aimed to assess the impact of the photon-counting detector (PCD)-CT-based virtual monoenergetic image (VMI) reconstruction keV levels on CT-based fractional flow reserve (CT-FFR), compared to the energy-integrating detector (EID)-CT. Methods: Patients undergoing clinically indicated coronary CT angiography (CCTA) on an EID-CT were prospectively enrolled for a research CCTA on a PCD-CT within 30 days. PCD-CT datasets were reconstructed at VMI levels of 45, 55, 70, and 90 keV. CT-FFR was obtained semiautomatically using an on-site machine learning algorithm by two readers. CT-FFR ≤ 0.80 was considered hemodynamically significant. Results: A total of 20 patients (63.3 ± 8.8 years; 13 men (65%) were included. Median CT-FFR values in the per-vessel analysis for PCD-CT scans were 0.86 (0.81–0.92) for 45 keV, 0.87 (0.80–0.93) for 55 keV, 0.85 (0.79–0.92) for 70 keV and 0.82 (0.76–0.89) for 90 keV, and 0.86 (0.71–0.93) for EID-CT. Comparison among different VMIs showed significant differences only for 45 vs. 90 keV (p < 0.001), and 55 vs. 90 keV (p < 0.001). No significant differences were found in the pairwise comparison between any VMI and EID-CT (all p > 0.05). PCD-CT at 70 keV showed the highest correlation (r = 0.83, p < 0.001), agreement (ICC: 0.90 (0.84–0.94)), and the lowest bias (mean bias −0.01; limits of agreement, 0.84/0.94) when compared to EID-CT. Conclusion: VMI reconstructions showed significant influence on CT-FFR values only at the extreme levels of the spectrum, while no significant differences were found in comparison with EID-CT. VMI at 70 keV demonstrates the highest correlation and agreement, with the lowest bias compared to EID-CT. Critical relevance statement: Evidence on novel spectral photon-counting detector (PCD)-CT’s impact on CT-fractional flow reserve (FFR) is limited; our results demonstrate the feasibility of CT-FFR using PCD-CT, showing no significant differences between various virtual monoenergetic images and energy-integrating detector (EID)-CT values Key Points: The impact of spectral photon-counting detector (PCD)-CT on CT-derived fractional flow reserve (CT-FFR) is unclear. Spectral PCD-CT-based CT-FFR is feasible, differing only at extreme virtual monoenergetic image levels. CT-FFR from PCD-CT at 70 keV showed the strongest correlation with energy-integrating detector-CT.

Cite

CITATION STYLE

APA

Tremamunno, G., Pinos, D., Zsarnoczay, E., Schoepf, U. J., Vecsey-Nagy, M., Gnasso, C., … Varga-Szemes, A. (2025). Influence of virtual monoenergetic reconstructions on coronary CT angiography-based fractional flow reserve with photon-counting detector CT: intra-individual comparison with energy-integrating detector CT. Insights into Imaging, 16(1). https://doi.org/10.1186/s13244-025-01927-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free