Estimation of body composition and water data depends on the bioelectrical impedance device

10Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Overweight, obese and chronic kidney disease patients have an altered and negative body composition being its assessment important. Bioelectrical impedance analysis is an easy-to-operate and low-cost method for this purpose. This study aimed to compare and correlate data from single- A nd multi-frequency bioelectrical impedance spectroscopy applied in subjects with different body sizes, adiposity, and hydration status. It was a cross-sectional study with 386 non-chronic kidney disease volunteers (body mass index from 17 to 40 kg/m2), 30 patients in peritoneal dialysis, and 95 in hemodialysis. Bioelectrical impedance, body composition, and body water data were assessed with single- A nd multi-frequency bioelectrical impedance spectroscopy. Differences (95% confidence interval) and agreements (Bland-Atman analyze) between devices were evaluated. The intraclass correlation coefficient was used to measure the strength of agreement and Pearson's correlation to measure the association. Regression analyze was performed to test the association between device difference with body mass index and overhydration. The limits of agreement between devices were very large. Fat mass showed the greatest difference and the lowest intraclass and Pearson's correlation coefficients. Pearson's correlation varied from moderate to strong and the intraclass correlation coefficient from weak to substantial. The difference between devices were greater as body mass index increased and was worse in the extremes of water imbalance. In conclusion, data obtained with single- A nd multi-frequency bioelectrical impedance spectroscopy were highly correlated with poor agreement; the devices cannot be used interchangeably and the agreement between the devices was worse as body mass index and fat mass increased and in the extremes of overhydration.

Cite

CITATION STYLE

APA

Bellafronte, N. T., Batistuti, M. R., Dos Santos, N. Z., Holland, H., Romaõ, E. A., & Chiarello, P. G. (2018). Estimation of body composition and water data depends on the bioelectrical impedance device. Journal of Electrical Bioimpedance, 9(1), 96–105. https://doi.org/10.2478/joeb-2018-0014

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free