Abstract
The aim of the experiment is to establish a method for the determination of acrylamide in food by automatic accelerated solvent extraction-gas chromatography-mass spectrometry. D3-acrylamide was used as isotope internal standard, crushed samples were extracted and purified by automatic accelerated solvent, acrylamide was derivatized into 2,3-dibromopropanamide by potassium bromide and potassium bromate under acidic conditions, and then the derivative was extracted by ethyl acetate and detected by gas chromatography-mass spectrometry. The method had a good linear relationship in the concentration range of 10–2000 ng/mL, and the coefficient of determination (R2) was 0.9997. The detection limit of the method was 3 mg/kg. The quantification limit of the method was 10 mg/kg. The standard addition recovery of acrylamide was between 105 and 120%, and the relative standard deviation of the recovery of acrylamide was less than 3.0%. The experimental result showed that the method was simple, sensitive, efficient and accurate, and could be used for the determination of acrylamide in food.
Author supplied keywords
Cite
CITATION STYLE
Kang, C., Ma, H., Li, Y., Zhang, C., Hong, Y., & Shao, M. (2021). Determination of acrylamide in foods by automatic accelerated solvent extraction and gas chromatography-mass spectrometry. Acta Chromatographica, 33(1), 64–72. https://doi.org/10.1556/1326.2020.00755
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.