In vitro performance of near infrared light transillumination at 780-nm and digital radiography for detection of non-cavitated approximal caries

45Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objectives To evaluate the ability of a Near Infrared Light Transillumination (NILT) device to detect non-cavitated approximal caries lesions; and to compare its performance to Digital Radiography (DR). Methods Thirty human extracted premolars (sound to lesions into the outer one-third of dentin) were selected. Lesion depth was confirmed by micro-computed tomography (μ-CT). Teeth were mounted in a custom-made device to simulate approximal contact. DR and NILT (CariVu™, DEXIS, LLC, Hatfield, PA, USA) examinations were performed and repeated by three trained and calibrated examiners. Sensitivity, specificity, area under ROC curve (Az), inter- and intra-class correlation coefficients (ICCs) for each method, and correlation among the methods were determined. Results ICCs for intra-/inter-examiner agreement were substantial for NILT (0.69/0.64), and moderate for DR (0.52/0.48). Sensitivity/specificity for NILT and DR were 0.68/0.93 and 0.50/0.64, respectively. Az for NILT was 0.81, while for DR it was 0.61. Spearman correlation coefficient with μ-CT for NILT (0.65, p < 0.001) demonstrated moderate association, while that of DR suggested no association (0.19, p = 0.289). Conclusion Within the limitations of this in vitro study, NILT demonstrated a potential for early approximal caries detection. NILT and DR performed the same regarding the accuracy for non-cavitated approximal caries detection; however, NILT was superior to DR in terms of repeatability, agreement and correlation with μ-CT. Clinical significance A commercial version of NILT was recently introduced as a non-irradiative adjunctive caries detection method. It uses near infrared (NIR) light at 780-nm to transilluminate teeth and captures live images from the occlusal surface. This study demonstrates that NILT can be used as an alternative to radiography for non-cavitated approximal caries detection.

Cite

CITATION STYLE

APA

Abogazalah, N., Eckert, G. J., & Ando, M. (2017). In vitro performance of near infrared light transillumination at 780-nm and digital radiography for detection of non-cavitated approximal caries. Journal of Dentistry, 63, 44–50. https://doi.org/10.1016/j.jdent.2017.05.018

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free