Simplified dosimetry for kidneys and tumors in 177Lu-labeled peptide receptor radionuclide therapy

14Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To evaluate if satisfactory post-therapeutic image-based dosimetry can be achieved for Lu-177-DOTATATE treatments using a reduced number of image acquisitions to improve patient comfort and reduce economical costs. Methods: 39 patients who underwent 147 treatment cycles of Lu-177-DOTATATE for neuroendocrine tumors were included in the study. A total of 291 and 284 absorbed doses were calculated to kidneys and tumors, respectively. Single-point dosimetry was performed using one SPECT/CT image acquired at 1 d or 7 d post-treatment using a fixed effective half-life (Teff) or using a patient-specific Teff determined for the initial cycle. Also, dose-per-activity values, (D/A)1, were determined from the first cycle and used to calculate doses for subsequent cycles. All absorbed doses were evaluated against “true” doses calculated using both the 1 d and 7 d images. The relation between tumor grade and absorbed doses was also investigated. All dosimetry was performed on SPECT images. Results: Absorbed doses to kidneys were most accurate when single-point dosimetry was performed using 1 d images with median ratios in relation to “true” doses in total dose of 1.00 (IQR: 0.97–1.03) when using fixed Teff and 1.01 (IQR: 0.98–1.04) when using Teff from the initial cycle. Calculations based on the 7 d image were most accurate for tumors with corresponding ratios in total absorbed dose of 0.98 (IQR: 0.96–1.00) and 1.00 (IQR: 0.99–1.01) when using a fixed Teff or Teff from the first cycle, respectively. The (D/A)1 approach performed worse, as 2 of 77 total absorbed doses to the kidneys deviated with > 30%, and tumor-absorbed doses were increasingly overestimated with every cycle. Absorbed doses, Teff and 1 d uptake were higher for G1 tumors than G2 tumors. Conclusion: Dosimetry can be performed with satisfactory accuracy when using single SPECT/CT images acquired at 1 d for kidneys or at 7 d for tumors.

Cite

CITATION STYLE

APA

Ardenfors, O., Nilsson, J. N., Thor, D., & Hindorf, C. (2022). Simplified dosimetry for kidneys and tumors in 177Lu-labeled peptide receptor radionuclide therapy. EJNMMI Physics, 9(1). https://doi.org/10.1186/s40658-022-00473-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free