Impact of ultra-low dose CT acquisition on semi-automated RECIST tool in the evaluation of malignant focal liver lesions

7Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare the evaluation of malignant focal liver lesions (FLLs) using a semi-automated RECIST tool with a standard and an ultra-low dose (ULD) computed tomography (CT) protocol. Materials and methods: Thirty-four patients with malignant FLLs underwent two abdominal-pelvic CT examinations one using a standard protocol and one using an ULD protocol. There were 23 men and 11 women with a mean age 64.3 ± 14.4 (SD) years (range: 22–91 years). Dosimetric indicators were recorded, and effective dose was calculated for both examinations. Mean malignant FLL attenuation, image noise and contrast-to-noise-ratio (CNR) were compared. The largest malignant FLL per patient was evaluated using the semi-automated RECIST tool to determine longest axis length, longest orthogonal axis length, volume and World Health Organisation area. Results: Dosimetric values were significantly reduced by −56% with ULD compared to standard protocol. No differences in mean malignant FLL attenuation values were found between the two protocols. Image noise was significantly increased for all locations (P < 0.05) with ULD compared to standard protocol, and CNR was significantly reduced (P < 0.05). On the 34 malignant FLLs analyzed, six semi-automated shapes non-concordant with radiologist's visual impression were highlighted with the software, including one FLL (1/34; 3%) with standard CT acquisition only, three FLLs (3/34; 9%) with ULD CT acquisition only and two FLLs (2/34; 6%) with both CT acquisitions. After manual editing, the concordance of the values of the studied criteria between both acquisitions was good and no significant difference was reported. Conclusion: Semi-automated RECIST tool demonstrates good performances using ULD CT protocol. It could be used in routine clinical practice with a ULD protocol for follow-up studies in patients with known malignant FLL.

Cite

CITATION STYLE

APA

Hamard, A., Frandon, J., Larbi, A., Goupil, J., De Forges, H., Beregi, J. P., & Greffier, J. (2020). Impact of ultra-low dose CT acquisition on semi-automated RECIST tool in the evaluation of malignant focal liver lesions. Diagnostic and Interventional Imaging, 101(7–8), 473–479. https://doi.org/10.1016/j.diii.2020.05.003

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free