Room-temperature scavengers for macromolecular crystallography: Increased lifetimes and modified dose dependence of the intensity decay

35Citations
Citations of this article
63Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The advent of highly intense wiggler and undulator beamlines has reintroduced the problem of X-ray radiation damage in protein crystals even at cryogenic temperatures (100 K). Although cryocrystallography can be utilized for the majority of protein crystals, certain macromolecular crystals (e.g. of viruses) suffer large increases in mosaicity upon flash cooling and data are still collected at room temperature (293 K). An alternative mechanism to cryocooling for prolonging crystal lifetime is the use of radioprotectants. These compounds are able to scavenge the free radical species formed upon X-ray irradiation which are thought to be responsible for part of the observed damage. Three putative radioprotectants, ascorbate, 1,4-benzoquinone and 2,2,6,6-tetramethyl-4-piperidone (TEMP), were tested for their ability to prolong lysozyme crystal lifetimes at 293 K. Plots of relative summed intensity against dose were used as a metric to assess radioprotectant ability: ascorbate and 1,4-benzoquinone appear to be effective, whereas studies on TEMP were inconclusive. Ascorbate, which scavenges OH radicals (k OH = 8 109 M -1 s-1) and electrons with a lower rate constant (k e-(aq) = 3.0 108 M -1 s-1), doubled the crystal dose tolerance, whereas 1,4-benzoquinone, which also scavenges both OH radicals (k OH = 1.2 109 M -1 s-1) and electrons (k e-(aq) = 1.2 1010 M -1 s-1), offered a ninefold increase in dose tolerance at the dose rates used. Pivotally, these preliminary results on a limited number of samples show that the two scavengers also induced a striking change in the dose dependence of the intensity decay from a first-order to a zeroth-order process. © 2009 International Union of Crystallography Printed in Singapore - All rights reserved.

Cite

CITATION STYLE

APA

Barker, A. I., Southworth-Davies, R. J., Paithankar, K. S., Carmichael, I., & Garman, E. F. (2009). Room-temperature scavengers for macromolecular crystallography: Increased lifetimes and modified dose dependence of the intensity decay. Journal of Synchrotron Radiation, 16(2), 205–216. https://doi.org/10.1107/S0909049509003343

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley