Abstract
Background: Arthroscopic coracoplasty is a procedure for patients affected by subcoracoid impingement. To date, there is no consensus on how much of the coracoid can be resected with an arthroscopic burr without compromising its stability. Purpose: To determine the maximum amount of the coracoid that can be resected during arthroscopic coracoplasty without leading to coracoid fracture or avulsion of the conjoint tendon during simulated activities of daily living (ADLs). Study Design: Controlled laboratory study. Methods: A biomechanical cadaveric study was performed with 24 shoulders (15 male, 9 female; mean age, 81 ± 7.9 years). Specimens were randomized into 3 treatment groups: group A (native coracoid), group B (3-mm coracoplasty), and group C (5-mm coracoplasty). Coracoid anatomic measurements were documented before and after coracoplasty. The scapula was potted, and a traction force was applied through the conjoint tendon. The stiffness and load to failure (LTF) were determined for each specimen. Results: The mean coracoid thicknesses in groups A through C were 7.2, 7.7, and 7.8 mm, respectively, and the mean LTFs were 428 ± 127, 284 ± 77, and 159 ± 87 N, respectively. Compared with specimens in group A, a significantly lower LTF was seen in specimens in group B (P =.022) and group C (P