Ultrasound image measurements of erector spinae muscle thickness at four spinal levels in adolescents with idiopathic scoliosis: reliability and concave-convex comparison

  • Richter A
  • Parent E
  • Kawchuk G
  • et al.
N/ACitations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Muscular characteristics in scoliosis are insufficiently documented. Ultrasound imaging measurements of extensor muscle thickness are commonly used in low back pain (LBP) [1] but not in scoliosis. Taking measurements of extensor muscle thickness may aid in exercise prescription for patients with adolescent idiopathic scoliosis (AIS) [2]. Purpose: The purpose of this study is to (1) determine the intra-rater reliability of erector spinae ultrasound thickness measurements at different spinal levels, and (2) determine the concave-convex differences in erector spinae thickness in patients with AIS. Methods: Nine patients with AIS (8 females) with a single thoracic curve, aged 13.5+/-1.8 years old, with mean Cobb angles of 39.4+/-9.1o, under observation or undergoing brace treatment were included. In a prone position, three ultrasound images of erector thickness were obtained on each side at L3, the upper end vertebra, lower-end vertebra and the apex of the curve in random order. A 5cm curvilinear probe was used to capture images of the erectors parasagittally over the facets. Thickness was measured using ImageJ as the distance from the facet to the first fascia line by an examiner blinded to image location and measurements. Reliability was estimated using Intraclass Correlation Coefficients (ICC2,1 and 2,2) and standard error of measurement (SEM). Differences between sides were determined using paired t-tests at each level. Results: The intrarater ICCs(2,1) for a single measurement varied between 0.75 and 0.99. The ICCs(2,2) corresponding to the average of the most similar two out of three measurements varied between 0.86 and 0.99, depending on levels. The corresponding SEM for these average measurements varied between 0.03 and 0.17cm (mean 0.09), depending on sides and levels with no systematic pattern. The only statistically significant difference between sides was observed at the upper-end vertebra (concave

Cite

CITATION STYLE

APA

Richter, A., Parent, E. C., Kawchuk, G., Moreau, M., Hedden, D., & Lou, E. (2013). Ultrasound image measurements of erector spinae muscle thickness at four spinal levels in adolescents with idiopathic scoliosis: reliability and concave-convex comparison. Scoliosis, 8(S2). https://doi.org/10.1186/1748-7161-8-s2-o36

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free