Vascular time-activity variation in patients undergoing 123I-MIBG myocardial scintigraphy: Implications for quantification of cardiac and mediastinal uptake

13Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: For the quantification of cardiac 123I- metaiodobenzylguanidine (MIBG) uptake, the mediastinum is commonly used as a reference region reflecting nonspecific background activity. However, variations in the quantity of vascular structures in the mediastinum and the rate of renal clearance of 123I-MIBG from the blood pool may contribute to increased interindividual variation in uptake. This study examined the relationship between changes in heart (H) and mediastinal (M) counts and the change in vascular 123I-MIBG activity, including the effect of renal function. Methods: Fifty-one subjects with ischemic heart disease underwent early (15 min) and late (4 h) anterior planar images of the chest following injection of 123I-MIBG. Vascular 123I-MIBG activity was determined from venous blood samples obtained at 2 min, 15 min, 35 min, and 4 h post-injection. From the vascular clearance curve of each subject, the mean blood counts/min per ml at the time of each acquisition and the slope of the clearance curve were determined. Renal function was expressed as the estimated creatinine clearance (e-CC) and the estimated glomerular filtration rate (e-GFR). Relations between H and M region of interest (ROI) counts/pixel, vascular activity, and renal function were then examined using linear regression. Results: Changes in ROI activity ratios between early and late planar images could not be explained by blood activity, the slope of the vascular clearance curves, or estimates of renal function. At most 3% of the variation in image counts could be explained by changes in vascular activity (p=0.104). The e-CC and e-GFR could at best explain approximately 1.5% of the variation in the slopes of the vascular clearance curve (p=0.194). Conclusion: The change in measured H and M counts between early and late planar 123I-MIBG images is unrelated to intravascular levels of the radiopharmaceutical. This suggests that changes in M counts are primarily due to decrease in soft tissue activity and scatter from the adjacent lungs. © 2011 The Author(s).

Cite

CITATION STYLE

APA

Verberne, H. J., Verschure, D. O., Somsen, G. A., Van Eck-Smit, B. L. F., & Jacobson, A. F. (2011). Vascular time-activity variation in patients undergoing 123I-MIBG myocardial scintigraphy: Implications for quantification of cardiac and mediastinal uptake. European Journal of Nuclear Medicine and Molecular Imaging, 38(6), 1132–1138. https://doi.org/10.1007/s00259-011-1783-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free