Evaluation of two techniques for viral load monitoring using dried blood spot in routine practice in Vietnam (French National Agency for AIDS and Hepatitis Research 12338)

20Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Although it is the best method to detect early therapeutic failure, viral load (VL) monitoring is still not widely available in many resource-limited settings because of difficulties in specimen transfer, personnel shortage, and insufficient laboratory infrastructures. Dried blood spot (DBS) use, which was introduced in the latest World Health Organization recommendations, can overcome these difficulties. This evaluation aimed at validating VL measurement in DBS, in a laboratory without previous DBS experience and in routine testing conditions. Methods. Human immunodeficiency virus (HIV)-infected adults were observed in a HIV care site in Hanoi, and each patient provided 2 DBS cards with whole blood spots and 2 plasma samples. Viral load was measured in DBS and in plasma using the COBAS Ampliprep/TaqMan and the Abbott RealTime assays. To correctly identify those with VL ≥ 1000 copies/mL, sensitivity and specificity were estimated. Results. A total of 198 patients were enrolled. With the Roche technique, 51 plasma VL were ≥1000 copies/mL; among these, 28 presented a VL in DBS that was also ≥1000 copies/mL (sensitivity, 54.9; 95% confidence interval [CI], 40.3-68.9). On the other hand, all plasma VL < 1000 copies/mL were also <1000 copies/mL in DBS (specificity, 100; 95% CI, 97.5-100).With the Abbott technique, 45 plasma VL were ≥1000 copies/mL; among these, 42 VL in DBS were also ≥1000 copies/mL (sensitivity, 93.3%; 95% CI, 81.7-98.6); specificity was 94.8 (95% CI, 90.0-97.7). Conclusions. The Abbott RealTime polymerase chain reaction assay provided adequate VL results in DBS, thus allowing DBS use for VL monitoring.

Cite

CITATION STYLE

APA

Taieb, F., Tram, T. H., Ho, H. T., Pham, V. A., Nguyen, H. L., Pham, B. H., … Madec, Y. (2016). Evaluation of two techniques for viral load monitoring using dried blood spot in routine practice in Vietnam (French National Agency for AIDS and Hepatitis Research 12338). Open Forum Infectious Diseases, 3(3). https://doi.org/10.1093/ofid/ofw142

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free