Abstract
Objectives: To evaluate the impact that an electronic ordering system has on the rate of rejection of blood type and screen testing samples and the impact on the number of ABO blood-type discrepancies over a 4-year period. Methods: An electronic ordering system was implemented in May 2011. Rejection rates along with reasons for rejection were tracked between January 2010 and December 2013. Results: A total of 40,104 blood samples were received during this period, of which 706 (1.8%) were rejected for the following reasons: 382 (54.0%) unsigned samples, 235 (33.0%) mislabeled samples, 57 (8.0%) unsigned requisitions, 18 (2.5%) incorrect tubes, and 14 (1.9%) ABO discrepancies. Of the samples, 2.5% were rejected in the year prior to implementing the electronic ordering system compared with 1.2% in the year following implementation (P
Author supplied keywords
Cite
CITATION STYLE
Forest, S. K., Shirazi, M., Wu-Gall, C., & Stotler, B. A. (2017). The impact of an electronic ordering system on blood bank specimen rejection rates. In American Journal of Clinical Pathology (Vol. 147, pp. 105–109). Oxford University Press. https://doi.org/10.1093/AJCP/AQW204