On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples

29Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Abstract Background: Chromium (VI) has toxic and carcinogenic effects. So, determination and speciation of chromium in environmental samples is very important in view of health hazards. In this study, solid phase extraction (SPE) based on bulky amine-functionalized bimodal mesoporous silica nanoparticles (NH 2 -UVM-7) as a novel nanoadsorbent was applied for preconcentration and speciation of chromium (III, VI) in water samples. Methods: UVM-7 was synthesized via atrane route and subsequently functionalized with amino silane via grafting method. In SPE procedure, polymer tubing as a micro-column was filled with NH 2 -UVM-7 adsorbent. Preconcentration and speciation of Cr (III) and Cr (VI) ions with NH 2 -UVM-7 were obtained in water samples due to the fact that only Cr (VI) ions can be complexed with-NH 2 groups at optimized pH. Finally, chromium concentration was determined by flame atomic absorption spectrometry (F-AAS). Results: TEM, XRD, and SEM results confirmed the beneficial properties of NH 2 -UVM-7 as the adsorbent for chromium extraction. Under the optimal conditions, linear calibration curve, detection limit and preconcentration factor were obtained 6-320 μg/ L, 1.2 μg/L and 66.7, respectively (RSD < 5 %). The efficiency of nanoadsorbent for preconcentration and extraction of Cr (VI) was 96 %, whereas it was less than 5 % for Cr (III). Conclusions: The developed NH 2 -UVM7-based SPE/F-AAS method has enough sensitively and simplicity for speciation and determination of Cr (VI) and Cr (III) ions in real water samples. Good recoveries, with low detection limits and good preconcentration factors are the main advantages of this procedure.

Cite

CITATION STYLE

APA

Shirkhanloo, H., Khaligh, A., Golbabaei, F., Sadeghi, Z., Vahid, A., & Rashidi, A. (2015). On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples. Journal of Environmental Health Science and Engineering, 13(1). https://doi.org/10.1186/s40201-015-0205-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free