Detection of residual brain arteriovenous malformations after radiosurgery: Diagnostic accuracy of contrast-enhanced three-dimensional time of flight MR angiography at 3.0 Tesla

20Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

Abstract

Objective: Although three-dimensional time-of-flight magnetic resonance angiography (3D TOF-MRA) is used frequently as a follow-up tool to assess the response of arteriovenous malformations (AVMs) after radiosurgery, the diagnostic accuracy of 3D TOF-MRA is not well known. We evaluated the diagnostic accuracy of contrast-enhanced 3D TOF-MRA at 3.0 Tesla for the detection of residual AVMs. Materials and Methods: This study included 32 AVMs from 32 patients who had been treated with radiosurgery (males/females: 21/11; average patient age, 33.1 years). The time interval between radiosurgery and MRA was an average of 35.3 months (range, 12-88 months). Three-dimensional TOF-MRA was obtained at a magnetic field strength of 3.0 Tesla after infusion of contrast media, with a measured voxel size of 0.40 × 0.80 × 1.4 (0.45) mm3 and a reconstructed voxel size of 0.27 × 0.27 × 0.70 (0.05) mm3 after zero-filling. X-ray angiography was performed as the reference of standard within six months after MRA (an average of two months). To determine the presence of a residual AVM, the source images of 3D TOF-MRA were independently reviewed, focusing on the presence of abnormally hyperintense fine tangled or tubular structures with continuity as seen on consecutive slices by two observers blinded to the X-ray angiography results. Results: A residual AVM was identified in 10 patients (10 of 32, 31%) on X-ray angiography. The inter-observer agreement for MRA was excellent (κ= 0.813). For the detection of a residual AVM after radiosurgery as determined by observer 1 and observer 2, the source images of MRA had an overall sensitivity of 100%/90% (10 of 10, 9 of 10), specificity of 68%/68% (15 of 22, 15 of 22), positive predictive value of 59%/56% (10 of 17, 9 of 16), negative predictive value of 100%/94% (15 of 15, 15 of 16) and diagnostic accuracy of 78%/75% (25 of 32, 24 of 32), respectively. Conclusion: The sensitivity of contrast-enhanced 3D TOF-MRA at 3.0 Tesla is high but the specificity is not sufficient for the detection of a residual AVM after radiosurgery.

Cite

CITATION STYLE

APA

Kyoung, E. L., Choong, G. C., Jin, W. C., Byung, S. C., Deok, H. L., Sang, J. K., & Do, H. K. (2009). Detection of residual brain arteriovenous malformations after radiosurgery: Diagnostic accuracy of contrast-enhanced three-dimensional time of flight MR angiography at 3.0 Tesla. Korean Journal of Radiology, 10(4), 333–339. https://doi.org/10.3348/kjr.2009.10.4.333

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free