Retest reliability of measuring hip extensor muscle strength in different testing positions in young people with cerebral palsy

13Citations
Citations of this article
84Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In young people with spastic diplegic cerebral palsy weakness of the hip extensor muscles are associated with limitations in activity. It is important that clinicians can reliably measure hip extensor muscle strength to monitor changes over time and the effects of any interventions. Previous research has demonstrated high reliability for measuring strength of all muscles of the lower limb, with the exception of the hip extensors. Therefore the aim of this study was to examine the retest reliability of measuring hip extensor strength in young people with cerebral palsy.Methods: Using a test-retest reliability research design, 19 participants with spastic diplegic cerebral palsy (Gross Motor Function Classification System Levels II and III) (mean 19 y 2 mo [S D 2 y 5 mo]) attended two testing sessions held 12 weeks apart. Three trials with a hand-held dynamometer were taken at each testing session in supine, prone and standing. Retest reliability was calculated with Intraclass Correlation Coefficients (ICC(2,1)) and with units of measurement (kilograms) converted to a percentage strength change.Results: ICC values ranged from .74 to .78 in supine, .75 to .80 in prone, and .73 to .75 in standing. To be 95% confident that real change had occurred, an individual's strength would need to increase 55 to 60% in supine, 86 to 102% in prone, and 102 to 105% in standing. To be 95% confident that real change had occurred across groups, strength would need to increase 4 to 8% in supine, 22 to 31% in prone, and 32% to 34% in standing. Higher ICC values were observed when three trials were used for testing.Conclusions: The supine testing position was more reliable than the prone or standing testing positions. It is possible to measure hip extensor strength with sufficient reliability to be able monitor change within groups using the supine position provided three trials are used during testing. However, there is insufficient reliability to monitor changes in hip extensor strength in individuals with cerebral palsy unless they exhibit very large strength increases. © 2011 Dyball et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Dyball, K. M., Taylor, N. F., & Dodd, K. J. (2011). Retest reliability of measuring hip extensor muscle strength in different testing positions in young people with cerebral palsy. BMC Pediatrics, 11. https://doi.org/10.1186/1471-2431-11-42

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free