Development of a LAG-3 immunohistochemistry assay for melanoma

12Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Aims A robust immunohistochemistry (IHC) assay was developed to detect lymphocyte-activation gene 3 (LAG-3) expression by immune cells (ICs) in tumour tissues. LAG-3 is an immuno-oncology target with demonstrable clinical benefit, and there is a need for a standardised, well-characterised assay to measure its expression. This study aims to describe LAG-3 scoring criteria and present the specificity, sensitivity, analytical precision and reproducibility of this assay. Methods The specificity of the assay was investigated by antigen competition and with LAG3 knockout cell lines. A melanin pigment removal procedure was implemented to prevent melanin interference in IHC interpretation. Formalin-fixed paraffin-embedded (FFPE) human melanoma samples with a range of LAG-3 expression levels were used to assess the sensitivity and analytical precision of the assay with a ≥1% cut-off to determine LAG-3 positivity. Interobserver and intraobserver reproducibility were evaluated with 60 samples in intralaboratory studies and 70 samples in interlaboratory studies. Results The LAG-3 IHC method demonstrated performance suitable for analysis of LAG-3 IC expression in clinical melanoma samples. The pretreatment step effectively removed melanin pigment that could interfere with interpretation. LAG-3 antigen competition and analysis of LAG3 knockout cell lines indicated that the 17B4 antibody clone binds specifically to LAG-3. The intrarun repeatability, interday, interinstrument, interoperator and inter-reagent lot reproducibility demonstrated a high scoring concordance (>95%). The interobserver and intraobserver reproducibility and overall interlaboratory and intralaboratory reproducibility also showed high scoring concordance (>90%). Conclusions We have demonstrated that the assay reliably assesses LAG-3 expression in FFPE human melanoma samples by IHC.

Cite

CITATION STYLE

APA

Johnson, L., McCune, B., Locke, D., Hedvat, C., Wojcik, J. B., Schroyer, C., … Shuster, J. (2023). Development of a LAG-3 immunohistochemistry assay for melanoma. Journal of Clinical Pathology, 76(9), 591–598. https://doi.org/10.1136/jclinpath-2022-208254

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free