Impact of interventricular lead distance and the decrease in septal-to-lateral delay on response to cardiac resynchronization therapy

30Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims: To investigate the influence of interlead distance and lead positioning on success of cardiac resynchronization therapy (CRT) in patients with advanced chronic heart failure and electrical dyssynchrony. Despite application of established selection criteria, 20-40% of the patients do not respond to CRT. Methods and results: We examined consecutive patients in whom CRT was implanted. Response to CRT was defined as a decrease in the left ventricular end-systolic volume ≥10% after 6 months. A comparison was made between patients who were responders to CRT and those who were non-responders. A univariate and stepwise multivariate logistic regression was performed with regard to predictors for response. Between January 2004 and January 2008, 174 patients who were treated with CRT were classified as responders [n = 95 (55%)] or non-responders [n = 79 (45%)]. Responders had a significantly larger horizontal interlead distance on the lateral thoracic X-ray [odds ratio (OR) 2.8 (1.2-6.6), P = 0.01], a septal-to-lateral delay >60 ms [OR 4.9 (2.0-11.4), P < 0.0001], non-ischaemic cardiomyopathy [OR 3.0 (1.3-6.9), P = 0.009], a left ventricular end-diastolic diameter <67 mm [OR 4.2 (1.8-9.9), P = 0.001], angiotensin-converting enzyme inhibitor use [OR 8.1 (1.7-38.2), P = 0.008], and no tricuspid valve insufficiency [OR 6.9 (1.3-35.5), P = 0.02]. Post-implantation responders had a significantly greater decrease in the intraventricular delay (septal-to-lateral delay 62 ± 62 vs. 26 ± 65 ms, P = 0.001), but not in the interventricular mechanical delay. Conclusion: Larger interlead distance on the lateral thoracic X-ray, associated with positioning of the left ventricular lead in the posterior position, is associated with response after 6 months of follow-up. Furthermore, diminishing the septal-to-lateral delay is predictive for response. © The Author 2008.

Cite

CITATION STYLE

APA

Buck, S., Maass, A. H., Nieuwland, W., Anthonio, R. L., Van Veldhuisen, D. J., & Van Gelder, I. C. (2008). Impact of interventricular lead distance and the decrease in septal-to-lateral delay on response to cardiac resynchronization therapy. Europace, 10(11), 1313–1319. https://doi.org/10.1093/europace/eun208

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free