Detecting glaucoma with a portable brain-computer interface for objective assessment of visual function loss

83Citations
Citations of this article
96Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

IMPORTANCE: The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. OBJECTIVE: To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. DESIGN, SETTING, AND PARTICIPANTS: This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. MAIN OUTCOMES AND MEASURES: Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. RESULTS: Among the33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P =.03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P =.01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. CONCLUSIONS AND RELEVANCE: The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.

Cite

CITATION STYLE

APA

Nakanishi, M., Wang, Y. T., Jung, T. P., Zao, J. K., Chien, Y. Y., Diniz-Filho, A., … Medeiros, F. A. (2017). Detecting glaucoma with a portable brain-computer interface for objective assessment of visual function loss. JAMA Ophthalmology, 135(6), 550–557. https://doi.org/10.1001/jamaophthalmol.2017.0738

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free