Monitoring offshore wind farm power performance with SCADA data and an advanced wake model

20Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

Abstract

Wind farm underperformance can lead to significant losses in revenues. The efficient detection of wind turbines operating below their expected power output and immediate corrections help maximize asset value. The method, presented in this paper, estimates the environmental conditions from turbine states and uses pre-calculated lookup tables from a numeric wake model to predict the expected power output. Deviations between the expected and the measured power output ratio between two turbines are an indication of underperformance. The confidence of detected underperformance is estimated by a detailed analysis of the uncertainties of the method. Power normalization with reference turbines and averaging several measures performed by devices of the same type can reduce uncertainties for estimating the expected power. A demonstration of the method's ability to detect underperformance in the form of degradation and curtailment is given. An underperformance of 8 % could be detected in a triple-wake condition.

Cite

CITATION STYLE

APA

Mittelmeier, N., Blodau, T., & Kühn, M. (2017). Monitoring offshore wind farm power performance with SCADA data and an advanced wake model. Wind Energy Science, 2(1), 175–187. https://doi.org/10.5194/wes-2-175-2017