Three different tools for Digital Image Correlation (DIC) were used for evaluation of dynamic experiments performed using custom Open Hopkinson Pressure Bar (OHPB) apparatus. High strain-rate measurements were performed on specimens of advanced cellular materials with predefined structure and negative Poisson’s ratio. Low impedance polymethyl methacrylate (PMMA) bars instrumented with foil strain-gauges were used for dynamic loading of the specimens. Experiments were observed using a pair of high-speed cameras for imaging of loading process in sufficient quality. Custom developed evaluation DIC tool implemented in Matlab, open-source Matlab tool (NCorr) and commercial DIC software (ISTRA 4D) were all used for evaluation of image sequences recorded by high-speed cameras. Comparison of results obtained using all three different DIC tools and results of complementary strain-gauge measurement are shown in this paper. Verification of reliability of custom made DIC software tool is presented.