Study Design: Retrospective cohort study. Objective: To assess both implant performance and the amount of correction that can be achieved using multilevel anterior lumbar interbody fusion (ALIF). Methods: Retrospective cohort study (n = 178) performed over a 4-year period. Surgical variables examined included blood loss, operative time, perioperative complications, and secondary/revision procedures. Follow-up radiographic assessment was performed to record implant-related problems. Radiographic parameters were examined pre- and postoperatively. Health-related quality of life (HRQOL) outcome measures were collected preoperatively and at 6 weeks, 6 months, 1 year, and 2 years postoperatively. Descriptive and comparative statistical analysis, using paired-sample t test and repeated-measures analysis of variance (rANOVA), was performed. Results: Lumbar lordosis increased from 42° ± 17° preoperatively to 55° ± 11° postoperatively (P
CITATION STYLE
Butler, J. S., Lui, D. F., Malhotra, K., Suarez-Huerta, M. L., Yu, H., Selvadurai, S., … Molloy, S. (2019). 360-Degree Complex Primary Reconstruction Using Porous Tantalum Cages for Adult Degenerative Spinal Deformity. Global Spine Journal, 9(6), 613–618. https://doi.org/10.1177/2192568218814531