Imaging quality evaluation of low tube voltage coronary CT angiography using low concentration contrast medium

18Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To compare the image quality of prospectively ECG-gated low voltage coronary computed tomography angiography (CTA) with an administration of low concentration contrast medium. Method and Materials: A total of 101 patients, each with a heart rate below 65 beats per minute (BPM), underwent a prospectively ECG-gated axial scan in CT coronary angiography on a 64-slice CT scanner. All patients were allocated in three groups (group A: n=31, 80kVp, 300 mgI/ml; group B: n=34, 100kVp, 300 mgI/ml; group C: n=36, 120kVp, 370 mgI/ml). The CT attenuation values of aortic root (AR), left main coronary artery (LMA), right main coronary artery (RMA) and chest subcutaneous fat tissue were measured. The contrast-to-noise ratio (CNR) of AR, LMA and RMA were calculated according to the formulas below. The values of computed tomography dose index (CTDI) and dose-length product (DLP) were recorded. Image quality was assessed on a 5-point scale. The results were compared using the one-way ANOVA and rank sum tests. Results: The values of CNR and SNR for vessels in group A and group B were not significantly different from group C (each p > 0.05). The effective radiation dose in group A (1.51±0.70 mSv) and group B (2.59±1.24 mSv) were both lower than group C (4.92±2.82 mSv) (each p < 0.05). There was no significant difference among the image quality scores of group A (4.10±0.41), group B (3.90±0.48) and group C (4.04±0.36) (each P > 0.05). Conclusion: Low tube voltage coronary CT angiography using low concentration contrast medium does not affect the imaging quality for assessing the coronary arteries compared with high voltage coronary CT angiography using high concentration contrast medium. Meanwhile low concentration contrast medium allowed 47-69% of radiation dose reduction.

Cite

CITATION STYLE

APA

Zhang, C., Yu, Y., Zhang, Z., Wang, Q., Zheng, L., Feng, Y., … Li, K. (2015). Imaging quality evaluation of low tube voltage coronary CT angiography using low concentration contrast medium. PLoS ONE, 10(3). https://doi.org/10.1371/journal.pone.0120539

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free