Is there a difference between the primary stability of anodized and non-anodized mini screws subjected to repeated cycles of autoclave sterilization?

2Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Objectives: To determine if autoclave sterilization has any deleterious effects on the clinical stability of anodized versus non-anodized mini-screws. Materials and Methods: Thirty anodized and thirty non-anodized Aarhus System mini-screws (American Orthodontics, Sheboygan, WI) were utilized. Each group was divided into three test groups. In each group, miniscrews that were sterilized once using a steam autoclave (Statim 5000, SciCan USA, Canonsburg, Pa) served as the control group (n=10). The other two test groups involved mini-screws that were subjected to a repeated cycles of sterilization for five (n=10) and ten (n=10) times. All sixty mini-screws were inserted at a 90° angle into custom-designed synthetic blocks that simulated the average mandible of a healthy adult. The maximum insertion torque and the lateral displacement at 0.025, 0.05, 0.1, 0.25, 0.5, and 1 mm were recorded for each sample and subjected to statistical testing. A two-way ANOVA, and a three-way mixed ANOVA were used for statistical analyses. Results: Maximum insertion torque values displayed significant differences between the anodized and nonanodized groups (p<0.001) as well as the sterilization cycles (p<0.001). No significant group and cycle interaction was observed. No significant differences were found between the groups and sterilization cycles in the evaluation of the lateral displacement test. However, there was a significant group/cycle/displacement interaction (p<0.001). Conclusions: Surface treatment of mini-screws with anodization produced differences when compared to standard surface mini-screws following autoclave sterilization. The differences between the two types of miniscrews did not indicate a potential stability concern.

Author supplied keywords

Cite

CITATION STYLE

APA

Ledingham, A. D., Şar, Ç., English, J. D., & Akyalçin, S. (2014). Is there a difference between the primary stability of anodized and non-anodized mini screws subjected to repeated cycles of autoclave sterilization? Cumhuriyet Dental Journal, 17(2), 129–134. https://doi.org/10.7126/cdj.58140.1008002195

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free