Device infections related to cardiac resynchronization therapy in clinical practice–An analysis of its prevalence, risk factors and routine surveillance at a single center university hospital

1Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The implantation rates of cardiac implantable electronic devices have steadily increased, accompanied by a steeper rise of device related infections (DRI). Hypothesis: The prevalence of DRI for cardiac resynchronization therapy (CRT) is higher in clinical practice than reported previously, even at a university hospital, and likely higher than reported to the national device registry. Methods: Electronic medical records of consecutive patients undergoing a CRT procedure between January 2016 and December 2017 were analyzed. Clinical history, procedure related variables and complications were reviewed by specialists in cardiology and infectious diseases. Results: A total of 171 patients, mean aged 74 years, 138 males (80.7%) were included. Twelve DRI occurred in 10 patients during mean 2.5 years follow-up, giving a prevalence of 7% (incidence of 29/1000 person-years). Reoperation, pocket haematoma, ≥3 procedures, previous device infection and indwelling central venous line were the strongest predictive factors according to univariate analysis. Out of 63/171 (36.8%) major complications, 31(49.2%) were lead-related. There were 49/171 (28.7%) reoperations and 15/171 (8.8%) minor complications. The number major complications and DRI reported to the national device registry were 7/171 (4.1%) and 2/171 (0.6%), respectively, reflecting a 5-fold underreporting. Conclusions: The high rate of CRT device infections is in sharp contrast to those reported by others and to the national device registry. Although a center specific explanation cannot be excluded, the high rates highlight a major issue with registries, reinforcing the need for better surveillance and automatic reporting of device related complications.

Cite

CITATION STYLE

APA

Ostrowska, B., Gkiouzepas, S., Kurland, S., & Blomström-Lundqvist, C. (2021). Device infections related to cardiac resynchronization therapy in clinical practice–An analysis of its prevalence, risk factors and routine surveillance at a single center university hospital. Clinical Cardiology, 44(6), 739–747. https://doi.org/10.1002/clc.23620

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free